Scope
The instrument is designed and manufactured in accordance with the requirements of the ASTM D3828,GB/T 5208 "Determination of the flash point of the rapid balance closed cup method", which can meet the requirements of petroleum, chemical, paint, paint, railway, aviation, electric power, commodity inspection, troops and The scientific research unit's requirements for the rapid test of closed flash point of petroleum products.
Features
1. Adopt Friend's special automatic ignition sensing system to automatically extinguish the fire when the fire occurs, to ensure the safety of the laboratory.
2. using a circular overall heating structure, heating more uniform, heating rate is more accurate
3. using air-cooled temperature control system to ensure that the furnace temperature is consistent
4. using automatic ignition, automatic opening, automatic detection, self-diagnosis function, one-button operation
5. with self-over temperature protection, over temperature range can be set freely
6. using touch screen display, real-time simulation tracking shows the function curve of heating and test time, real-time prompt function of operation interface
7. Adopting the pressure-limiting technology of independent intellectual property rights to ensure the uniform heat of the platinum wire and improve the accuracy of instrument detection.
8. using FLD special system, heating rate, ignition number can be set arbitrarily, simple and efficient
9. accuracy meets the requirements of GB/T 5208, configure standard samples
Technical parameter
1. Working power supply: AC 220V±10%, 50Hz
2. range: (low temperature type) -30 ° C -90 ° C
3. cooling mode: compressor refrigeration, automatic cycle
4. automatic degree: automatic opening, automatic ignition, automatic detection results, automatic printing
5. Ignition mode: electric ignition
6. adapt to the ambient temperature: 10-45 ° C
7. adapt to the environment humidity: <85%
8. the whole machine power consumption: 500W
Scope
The instrument is designed and manufactured in accordance with the requirements of the ASTM D3828,GB/T 5208 "Determination of the flash point of the rapid balance closed cup method", which can meet the requirements of petroleum, chemical, paint, paint, railway, aviation, electric power, commodity inspection, troops and The scientific research unit's requirements for the rapid test of closed flash point of petroleum products.
Features
1. Adopt Friend's special automatic ignition sensing system to automatically extinguish the fire when the fire occurs, to ensure the safety of the laboratory.
2. using a circular overall heating structure, heating more uniform, heating rate is more accurate
3. using air-cooled temperature control system to ensure that the furnace temperature is consistent
4. using automatic ignition, automatic opening, automatic detection, self-diagnosis function, one-button operation
5. with self-over temperature protection, over temperature range can be set freely
6. using touch screen display, real-time simulation tracking shows the function curve of heating and test time, real-time prompt function of operation interface
7. Adopting the pressure-limiting technology of independent intellectual property rights to ensure the uniform heat of the platinum wire and improve the accuracy of instrument detection.
8. using FLD special system, heating rate, ignition number can be set arbitrarily, simple and efficient
9. accuracy meets the requirements of GB/T 5208, configure standard samples
Technical parameter
1. Working power supply: AC 220V±10%, 50Hz
2. range: (low temperature type) -30 ° C -90 ° C
3. cooling mode: compressor refrigeration, automatic cycle
4. automatic degree: automatic opening, automatic ignition, automatic detection results, automatic printing
5. Ignition mode: electric ignition
6. adapt to the ambient temperature: 10-45 ° C
7. adapt to the environment humidity: <85%
8. the whole machine power consumption: 500W